GF333 Three Phase Multi-function Standard Meter

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Beijing
Validity to: Long-term effective
Last update: 2017-12-24 01:19
Browse the number: 167
inquiry
Company Profile
 
 
Product details
Introduction
GF333 three phase multi-function standard meter, its core part uses the DSP 32 bit and16 bit low power and high speed DAC consists of high accuracy AC collector. Not only it can be used as a calibration device standard meter, but also it can be used as a testing calibrator. Using 6.5 inch TFT color LCD screen, character display clear chart. Have the advantages of wide measuring range, high precision, stable and reliable operation, simple operation etc.
Functions and Features
1. Measure the AC voltage, current, active power, reactive power, frequency, phase angle and power factor etc;
2. Measure the AC voltage, current 2-31 harmonic content and waveform distortion degree;
3. Measure active power energy error, reactive power energy error, the maximum output pulse frequency is to 2 MHZ;
4. Measure calibration device of voltage, current, power stability;
5. Measure calibration device the standard deviation of estimate;
6. Measure the voltage of the calibration device three-phase symmetric degrees, the current of three three-phase symmetric degree;
7. Measure calibration device of the magnetic induction;
8. Measure DC voltage and DC current;
9. Transmitter measurement;
10. With RS232 interface, it can be controlled by PC operation;
Technical Data
AC measurement
L1/L2/L3 three phase voltage range (V) : 6.25, 12.5, 25, 50, 100, 200, 400, 800 V, Automatic switching, maximum 1000 V;
I1/I2/I3 three phase current range (A) : 0.25, 0.5, 1, 2.5, 5, 10, 25, 50, 100 A, Automatic switching;
Voltage, current, power measurement accuracy class
± (0.012% RD + 0.008% RG);
Power energy measurement accuracy class 0.02%;
Standard pulse output ≤2 MHz;
Frequency measurement range 45-65 Hz;
Frequency measurement accuracy 5 x 10-5;
Phase angle measurement error ±0.02 °;
Power factor measurement error ±0.0001;
Harmonic and distortion degree of measurement voltage/current
Harmonic number 2-31;
Harmonic error ±0.05%;
Distortion degree error ±0.05%;
DC measurements (optional)
Voltage range (V): 50, 100, 200, 400, 800, automatic switching, maximum 1000 V;
Current range (A): 0.1, 0.3, 1, 3, 10, 30, automatic switching;
Voltage, current measurement accuracy class
± (0.012% RD + 0.008% RG);
Transmitter measurement (optional)
DC voltage range:± 1, ± 5, ± 10, ± 20 V; Accuracy class 0.01%;
DC current range:± 1, ± 2.5, ± 5, ± 10, ± 20mA; Accuracy class 0.01%;
Ripple measurement error 1%;
Work power
Single phase AC 220 V±10%, frequency 50Hz/60Hz±5%
Use of the environment
Temperature 20 ℃±10 ℃, relative humidity ≤85% RH.
Volume
440 mm x 360 mm x 160 mm.
Weight
About 10 kg.